ILHS cable
The ILHS cable is a robust industrial thermal cable that can be used for applications that use process heat or maintain a temperature of up to 200 degrees Celsius
The advantage of the ILHS thermal cable is that it can be cut at any point to fit the required length. Without any precise calculations for the length you can use
ILHS cable model for use in non-hazardous, hazardous and corrosive environments according to internationally approved standards

Features of ILHS cable
The self-regulating features of the ILHs cable improve safety and reliability
The ILHS cable does not overheat or burn, even when it is placed sideways
The output and power of the ILHS cable is set in response to the temperature of the tube
You can cut the cable as much as you can and do not crash
Suitable for high temperature, holding temperature up to 150+ degrees Celsius
It has a wide range of terminals, controllers and accessories
Cables do not burn if they are placed together
Suitable for V AC120- 110(V AC277-220 according to its use )
Installing the Quintherm ILHS cable is quick and easy And do not need any special skills or tools.Termination components, fittings and power connections are provided in all appropriate cases

Technical Specifications
Power Output | 60W, 45 w, 31 w, 17 watts per meter at 10 degrees centigrade |
---|---|
External pod | Silicon or Fluoropolymer |
Maximum bright temperature | 150°C (212 ° F) |
Maximum offset temperature | 200°C (212 ° F) |
Minimum installation temperature | 40°C- |
Temperatures | T3 |
Voltage | 208-277W |
Maximum wear resistance | <18.2 Ω in km |
Technical Information
Power on | 150°C |
---|---|
Power off | 200°C |
Minimum installation temperature | 40°C - |
Minimum working temperature | 65°C - |
Power supply | 220-277VAC |
Maximum protective cover protection | ≤ 18,2 Ω/km |
Temperatures | T3 |
Available models
ILHS../Qx | ase heating tape without any braiding or outerja cket (only for non-Ex applications) (available upon special request) |
---|---|
ILHS..C/Qx | ase heating tape with tinned copper braid provid ing mechanical protection or where Traced equipment does not provide an effective ea rth path, e.g. plastic or non-metallic pipework or surfaces. (available upon special request) |
LHS..CS/Qx | ase heating tape with tinned copper braid and sil icone outerjacket for added Mechanical and light chemical protection. |
ILHS..CF/Qx | Base heating tape with tinned copper braid and flu oropolymer outerjacket for added mechanical and aggressive chemical protection |
Weights and Dimensions
Type | Dimensions Nominal (mm) | Weight kg/100 m | Min. Bending Radius (mm) | Gland Size |
---|---|---|---|---|
ILHS.. | 9,45x 4,05 | 6,6 | 20 | M20 |
ILHS..C | 10,45x 5,05 | 12,2 | 20 | M20 |
ILHS..CS | 12,45x 7,05 | 12,9 | 25 | M20 |
ILHS..CF | 11,35x 5,95 | 12,8 | 30 | M20 |
Maximum Critical Time (m) and Miniature Circuit Breaker (Amp)
Type | Start Temp | 230V AC | |||
---|---|---|---|---|---|
10A | 16A | 20A | 25A | ||
ILHS152 | 10°C | 76 | 122 | 154 | 154 |
0°C | 70 | 112 | 122 | 146 | |
20°C- | 62 | 98 | 140 | 138 | |
40°C- | 52 | 82 | 122 | 126 | |
ILHS302 | 10°C | 52 | 82 | 102 | 108 |
0°C | 46 | 74 | 92 | 104 | |
20°C- | 40 | 66 | 82 | 98 | |
40°C- | 30 | 50 | 62 | 88 | |
ILHS452 | 10°C | 38 | 62 | 76 | 88 |
0°C | 32 | 52 | 66 | 84 | |
20°C- | 24 | 38 | 46 | 76 | |
40°C- | 14 | 24 | 28 | 46 | |
ILHS602 | 10°C | 24 | 38 | 46 | 76 |
0°C | 18 | 30 | 36 | 58 | |
20°C- | 12 | 20 | 26 | 42 | |
40°C- | 8 | 12 | 16 | 24 |
To use “C” CB type according to EN60898-2: 2006
Thermal Ratings
- Technical Specifications
-
Technical Specifications
Power Output 60W, 45 w, 31 w, 17 watts per meter at 10 degrees centigrade External pod Silicon or Fluoropolymer Maximum bright temperature 150°C (212 ° F) Maximum offset temperature 200°C (212 ° F) Minimum installation temperature 40°C- Temperatures T3 Voltage 208-277W Maximum wear resistance <18.2 Ω in km Technical Information
Power on 150°C Power off 200°C Minimum installation temperature 40°C - Minimum working temperature 65°C - Power supply 220-277VAC Maximum protective cover protection ≤ 18,2 Ω/km Temperatures T3
- Available models
-
Available models
ILHS../Qx ase heating tape without any braiding or outerja
cket (only for non-Ex applications)
(available upon special request)ILHS..C/Qx
ase heating tape with tinned copper braid provid
ing mechanical protection or where
Traced equipment does not provide an effective ea
rth path, e.g. plastic or non-metallic
pipework or surfaces.
(available upon special request)LHS..CS/Qx
ase heating tape with tinned copper braid and sil
icone outerjacket for added
Mechanical and light chemical protection.ILHS..CF/Qx
Base heating tape with tinned copper braid and flu
oropolymer outerjacket for added
mechanical and aggressive chemical protection - Weights and Dimensions
-
Weights and Dimensions
Type Dimensions
Nominal (mm)Weight
kg/100
mMin. Bending
Radius (mm)Gland
SizeILHS.. 9,45x 4,05 6,6 20 M20 ILHS..C 10,45x 5,05 12,2 20 M20 ILHS..CS 12,45x 7,05 12,9 25 M20 ILHS..CF 11,35x 5,95 12,8 30 M20 - Flow protection
-
Maximum Critical Time (m) and Miniature Circuit Breaker (Amp)
Type Start
Temp230V AC 10A 16A 20A 25A ILHS152
10°C 76 122 154 154 0°C 70 112 122 146 20°C- 62 98 140 138 40°C- 52 82 122 126 ILHS302
10°C 52 82 102 108 0°C 46 74 92 104 20°C- 40 66 82 98 40°C- 30 50 62 88 ILHS452
10°C 38 62 76 88 0°C 32 52 66 84 20°C- 24 38 46 76 40°C- 14 24 28 46 ILHS602 10°C 24 38 46 76 0°C 18 30 36 58 20°C- 12 20 26 42 40°C- 8 12 16 24 To use “C” CB type according to EN60898-2: 2006
- Thermal curve
- Product components